Overview
Dimensions: 770 × 150 × 100 mm with four Ø4 mm mounting holes. Optionally available with an integrated control unit (CED-L) and RF wireless connection.
Key Features
Display & Operation
- 6-digit LED display with 3" (76 mm) or 4" (102 mm) character height
- IP54 aluminium profile enclosure with plexiglass front panel
- CED-3X: 620 × 150 × 100 mm • CED-4X: 770 × 150 × 100 mm
- LED indicators showing relay output status; 5-key keypad
- RS485/RS232 serial ports for continuous one-way ASCII transmission
Ordering Code
CED-4X| CEDProduct family | 4XSize (inch / mm) | –Control unit | 2Relays | 1Load cell inputs | MCommunication | 01Wireless | JOptional input |
|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
Technical Specifications
| Power supply and consumption | 24–48 VDC/VAC; 6 VA 24–250 VAC; 6 VA |
|---|---|
| Number of load cells • Load cell supply | up to 2 (350 Ω) • 4 VDC |
| Linearity | < 0.01% full scale |
| Thermal drift | < 0.002% full scale / °C |
| A/D converter | 24 bit |
| Measuring range | ±3.9 mV |
| Conversions per second | 3 |
| Decimals • Display increments | 0÷4 • x1 x2 x5 x10 x20 x50 |
| Digital filter | 0.25÷3 Hz |
| Relay outputs | Standard: 2 programmable control relays Optional: 4 programmable control relays 30 VDC / 250 VAC; 2 A |
| Opto-isolated digital inputs | 2 |
| Serial ports | RS485, RS232 |
| Baud rate | 1200, 2400, 9600, 19200, 38400, 57600, 115200 bit/s |
| Humidity (non-condensing) | 85% |
| Storage temperature | −30 °C … +60 °C |
| Operating temperature | −20 °C … +55 °C |
Certifications & Compliance
- CE certification for European Union countries.
- Category 2 as per EN 13849-1, PL d (comparable to SIL 2 level, EN 62061) (LCD3PL).
- Lead (Pb) free.
Options on Request
CASTL series polycarbonate box, 170 × 140 × 95 mm, transparent cover; versions with 4+2 M16×1.5 cable glands or PVC end fittings.
Integrated RF interface for connecting multiple units: 2.4 GHz (128 channels), average range 100 m.
COLM / SCM overload limiter control units.
The company reserves the right to change technical data, drawings and images without prior notice.