Home /Overload Control Systems /Control Units /CED-L
CED-L
Control Units

CED-L

External display with integrated overload control unit

CED-L combines a large external display and a complete overload limiter in one IP54 aluminium enclosure. The integrated control unit monitors up to two load cells, limits the load with pre-alarm and alarm thresholds and shows the load in large 3" or 4" LED digits that are clearly visible to the operator and the site.

6digit LED display
3" / 4"character height
Lintegrated control unit
IP54aluminium body

Overview

Load limitation is performed via a safety relay with guided contacts monitored in real time, with a dual-channel input system for double-bridge load cells in accordance with Category 2 as per EN 13849-1, PL d.

Key Features

Display & Operation

  • 6-digit LED display with 3" (76 mm) or 4" (102 mm) character height
  • IP54 aluminium profile enclosure with plexiglass front panel
  • CED-3X: 620 × 150 × 100 mm • CED-4X: 770 × 150 × 100 mm
  • LED indicators showing relay output status; 5-key keypad
  • RS485/RS232 serial ports for continuous one-way ASCII transmission

Integrated Control Unit (L)

  • Dual-channel input system for double-bridge load cells (Cat. 2, EN 13849-1, PL d)
  • Load limitation via safety relay with guided contacts, monitored in real time
  • Independent general alarm relay
  • 2 relays for general threshold intervention (e.g. pre-alarm / discharge system)
  • 3 changeover relay outputs (standard) or 4 relays incl. one safety relay (option)
  • 2 independent load cell inputs; alarm on load cell connection failure

Load Limiting

  • Load limitation by alarm and pre-alarm thresholds
  • Single and summed load limitation for systems with up to 2 weighing points by connecting multiple units
  • Lifting operation counters
  • When the load is below the set nominal value, the 3rd and 4th relays enable operation at the 3rd and 4th speed levels

Main Functions

  • Connection to PC/PLC via RS485/RS232
  • Connection to a remote display via RS485/RS232
  • Up to 2 load cells in parallel via junction box
  • Connection to other units for the summing function via RS485 or RF (option on request)
  • Continuous load cell connection integrity check
  • Digital filter to reduce the effects of load oscillation
  • Theoretical calibration (via keypad) and real calibration (with sample weights)
  • Tare weight zero setting
  • Automatic zero setting at power-on
  • Gross weight zero tracking

Ordering Code

ExampleCED-4X-L-2-1-M-01-J
CEDProduct family 4XSize (inch / mm) LControl unit 2Relays 1Load cell inputs MCommunication 01Wireless JOptional input
  • External display
  • 3X – 3" • 620×150×100
  • 4X – 4" • 770×150×100
  • None
  • L – Integrated
  • None
  • 2
  • 3
  • 4
  • None
  • 1
  • 2
  • M – Modbus
  • I – 4–20 mA
  • V – 0–10 V
  • 01 – None (cable)
  • 02 – Bluetooth
  • 03 – Wi-Fi
  • J – Gyroscope
  • W – Wind sensor

Technical Specifications

Power supply and consumption24–48 VDC/VAC; 6 VA
24–250 VAC; 6 VA
Number of load cells • Load cell supplyup to 2 (350 Ω) • 4 VDC
Linearity< 0.01% full scale
Thermal drift< 0.002% full scale / °C
A/D converter24 bit
Measuring range±3.9 mV
Conversions per second3
Decimals • Display increments0÷4 • x1 x2 x5 x10 x20 x50
Digital filter0.25÷3 Hz
Relay outputsStandard: 2 programmable control relays
Optional: 4 programmable control relays
30 VDC / 250 VAC; 2 A
Opto-isolated digital inputs2
Serial portsRS485, RS232
Baud rate1200, 2400, 9600, 19200, 38400, 57600, 115200 bit/s
Humidity (non-condensing)85%
Storage temperature−30 °C … +60 °C
Operating temperature−20 °C … +55 °C

Certifications & Compliance

  • CE certification for European Union countries.
  • Category 2 as per EN 13849-1, PL d (comparable to SIL 2 level, EN 62061) (LCD3PL).
  • Lead (Pb) free.

Options on Request

IP67 box

CASTL series polycarbonate box, 170 × 140 × 95 mm, transparent cover; versions with 4+2 M16×1.5 cable glands or PVC end fittings.

RF

Integrated RF interface for connecting multiple units: 2.4 GHz (128 channels), average range 100 m.

CLL / CLB

COLM / SCM overload limiter control units.

The company reserves the right to change technical data, drawings and images without prior notice.